UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2860 Replacing Project
Applications
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
| Ingredient | Effect |
| SS, Particles?> 1μm | Removal Rate?≥ 99% |
| SDI | ≤ 3 |
| Bacteria, Viruses | >?4 log |
| Turbidity | < 1NTU |
| TOC | Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 25NTU.
Product Parameters

Technical Parameters
| Filtering?Type | Outside-in |
| Membrane?Material | Modified?PVDF |
| MWCO | 200K Dalton |
| Membrane?Area | 52m2 |
| Membrane?ID/OD | 0.8mm/1.3mm |
| Dimensions | Φ225mm* 1860mm |
| Connector?Size | DN50 Clamping; Air?Inlet?– 10mm?air?pipe |
Application Data
| Pure?Water?Flux | 8,000L/H?(0.15MPa, 25℃) |
| Designed?Flux | 40-120L/m2.hr (0.15MPa, 25℃) |
| Suggested?Working?Pressure | ≤ 0.2MPa |
| Maximum?Transmembrane?Pressure | 0.15MPa |
| Maximum?Backwashing?Pressure | 0.15MPa |
| Air?Washing?Volume | 0.1-0.15N m3/m2 .hr |
| Air?Washing?Pressure | ≤ 0.1MPa |
| Maximum?Working?Temperature | 45℃ |
| PH?Range | Working: 4-10; Washing: 2-12 |
| Operating?Mode | Cross?Flow?or Dead End |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
| Turbidity | ≤ 25NTU |
| Oil?&?Grease | ≤?2mg/L |
| SS | ≤ 20mg/L |
| Total?Iron | ≤?1mg/L |
| Continuous?Residual?Chlorine | ≤?5ppm |
| COD | Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
| Backwashing?Flow?Rate | 100-150L/m2.hr |
| Backwashing?Frequency | Every?30-60min. |
| Backwashing?Duration | 30-60s |
| CEB?Frequency | 0-4?times per day |
| CEB?Duration | 5-10min. |
| CIP?Frequency | Every 1-3 months |
| Washing?Chemicals: | |
| Sterilization | 15ppm Sodium Hypochlorite |
| Organic?Pollution?Washing | 0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
| Inorganic?Pollution?Washing | 1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
| Component | Material |
| Membrane | Modified?PVDF |
| Sealing | Epoxy?Resins |
| Housing | UPVC |
description2


Send Email
Facebook
Twitter
Linkedin
Youtube